Cover: IT model non-contact open linear encoder- incremental read head
IT model non-contact open linear encoder- incremental read head
Manuals

IT model non-contact open linear encoder- incremental read head

Document details

Format
PDF
Size
1.5 MB
Pages
2
Version
V1.0
Updated

Description

This manual provides installation and technical specifications for the IT model non-contact open incremental linear encoder read head. It covers mounting procedures, LED status diagnostics, electrical characteristics, and connection options for Fagor and Yaskawa systems.

Intended for machine manufacturers and system integrators responsible for the installation, setup, and electrical connection of Fagor linear encoders.

Available languages

Technical data

Power Supply
5V (±10%) p. 2
Incremental Signal Period
0.1 μm to 20 μm p. 2
Max Cable Length
Up to 30 m p. 2
Mounting Spacer Thickness (ITA)
0.6 mm p. 1
Mounting Spacer Thickness (ITG/ITT)
0.2 mm p. 1

Data extracted from the document with AI and reviewed. Check the value on the indicated page.

Errors and alarms covered

CodeMeaningPage
Red LED Incorrect mounting, error, or low signal level. p. 1
Orange LED Poor setup, not allowed, or requires revision of cleanness and mounting. p. 1

List extracted from the document with AI and reviewed; it does not replace the manual. See the indicated page.